What is the purpose of adjusting sensitivity on a ventilator?

To enhance patient comfort

To improve tidal volume

To prevent auto-PEEP

To ensure synchronization with patient effort

The primary purpose of adjusting sensitivity on a ventilator is to ensure synchronization with the patient's effort. When a ventilator is properly synchronized with the patient's respiratory efforts, it can deliver breaths in harmony with the patient's natural inhalation and exhalation patterns. This synchronization helps to reduce patient-ventilator asynchrony, which can occur when the ventilator either responds too slowly or too quickly to the patient's attempts to breathe.

By adjusting the sensitivity settings, healthcare providers can find the optimal threshold that allows the ventilator to detect when the patient begins to initiate a breath. This ensures that the ventilator supports the patient’s efforts effectively, thereby enhancing ventilation and improving overall patient comfort. Proper synchronization is particularly important in critical care settings, as it can significantly impact the patient's ability to participate in their own respiratory management and maintain adequate gas exchange.